Insulation R-Value Chart by Climate Zone

Minimum insulation for every part of a house, by climate zone, from the 2021 and 2018 International Energy Conservation Code. Plus ENERGY STAR attic targets, R-value per inch for common materials, and batt thicknesses.

2021 IECC minimum R-values

This is the model code most states adopted or are moving to (Table R402.1.3). "ci" means continuous insulation, such as foam board over the outside of the studs; "13+5ci" means R-13 in the stud cavity plus R-5 continuous. Marine zone 4 (western Washington and Oregon) uses the zone 5 row.

ZoneAtticWood-frame wallFloorBasement wallSlab edgeCrawl space wallWindow U-factor
0 and 1R-30R-13, or R-10ciR-13None requiredNone requiredNone requiredNo requirement
2R-49R-13, or R-10ciR-13None requiredNone requiredNone requiredU-0.40
3R-49R-20, or 13+5ci, or R-15ciR-19R-5ci or R-13R-10, 2 ft deepR-5ci or R-13U-0.30
4 (except Marine)R-60R-30, or 20+5ci, or 13+10ci, or R-20ciR-19R-10ci or R-13R-10, 4 ft deepR-10ci or R-13U-0.30
5 and Marine 4R-60R-30, or 20+5ci, or 13+10ci, or R-20ciR-30R-15ci, or R-19, or 13+5ciR-10, 4 ft deepR-15ci, or R-19, or 13+5ciU-0.30
6R-60R-30, or 20+5ci, or 13+10ci, or R-20ciR-30R-15ci, or R-19, or 13+5ciR-10, 4 ft deepR-15ci, or R-19, or 13+5ciU-0.30
7 and 8R-60R-30, or 20+5ci, or 13+10ci, or R-20ciR-38R-15ci, or R-19, or 13+5ciR-10, 4 ft deepR-15ci, or R-19, or 13+5ciU-0.30

Mass walls (block, brick, ICF), skylights and solar heat gain limits are in the lookup tool results. Above 4,000 ft or in hurricane debris regions, zones 5 to 8 allow window U-0.32.

2018 IECC minimum R-values

Many states and cities still enforce the 2018 code (Table R402.1.2) or an older one. Compared with 2021, attics are one step lower (R-38 in zones 2 and 3, R-49 in zones 4 to 8) and walls in zones 4 and 5 have no R-30 option.

ZoneAtticWood-frame wallFloorBasement wallSlab edgeCrawl space wallWindow U-factor
1R-30R-13R-13None requiredNone requiredNone requiredNo requirement
2R-38R-13R-13None requiredNone requiredNone requiredU-0.40
3R-38R-20, or 13+5ciR-19R-5ci or R-13None requiredR-5ci or R-13U-0.32
4 (except Marine)R-49R-20, or 13+5ciR-19R-10ci or R-13R-10, 2 ft deepR-10ci or R-13U-0.32
5 and Marine 4R-49R-20, or 13+5ciR-30R-15ci or R-19R-10, 2 ft deepR-15ci or R-19U-0.30
6R-4920+5ci, or 13+10ciR-30R-15ci or R-19R-10, 4 ft deepR-15ci or R-19U-0.30
7 and 8R-4920+5ci, or 13+10ciR-38R-15ci or R-19R-10, 4 ft deepR-15ci or R-19U-0.30

ENERGY STAR recommendations for existing homes

If you're adding insulation to a house you already own, these are ENERGY STAR's targets. The "already has 3–4 inches" column is how much to add on top.

ZoneUninsulated atticAttic with 3–4 in. alreadyFloor
1R-30add R-25R-13
2R-49add R-38R-13
3R-49add R-38R-19
4A, 4BR-60add R-49R-19
4C, 5, 6R-60add R-49R-30
7, 8R-60add R-49R-38

R-value per inch by material

Use this to turn a target R-value into a thickness. Ranges are from US Department of Energy guides; actual values depend on the product and how well it's installed.

MaterialR per inchInches for R-30Inches for R-49
Blown fiberglass (loose fill)2.2–2.7~12"~20"
Blown cellulose (loose fill)2.9–3.8~9"~15"
Fiberglass batts2.9–3.8~9"~15"
Mineral wool battsabout 3.7~8"~13"
Open-cell spray foam3.5–3.8~8"~14"
Closed-cell spray foam6–7~5"~8"
EPS foam board3.8–4.4~8"~12"
XPS foam board5~6"~10"
Polyiso foam board5.6–8 (about 6.5 long-term)~5"~8"

Thickness columns use a typical mid value from each range. Loose fill settles, so follow the bag's "minimum settled thickness" for your target R-value.

Batt insulation sizes

Standard fiberglass batts come 15" wide for studs 16" on center and 23" wide for 24" on center. Thickness varies slightly by brand:

R-valueOwens CorningJohns ManvilleFits
R-113½"3½"2×4 walls
R-133½"3½"2×4 walls
R-153½"3½"2×4 walls (high density)
R-196¼"6½"2×6 walls (slightly compressed), floors
R-215½"5½"2×6 walls (high density)
R-309½"10¼"attics, floors over crawl spaces
R-3812"13"attics
R-4914"13½"attics

From Owens Corning and Johns Manville product data sheets. Cathedral-ceiling versions of R-30 and R-38 are thinner (8¼" and 10¼").

Frequently asked questions

What R-value insulation do I need in my attic?

Under the 2021 energy code: R-30 in zone 1, R-49 in zones 2 and 3, and R-60 in zones 4 to 8. ENERGY STAR gives the same targets for an uninsulated attic in an existing home. Find your zone with our ZIP code lookup.

What R-value goes in a 2×4 wall?

A 2×4 stud cavity is 3½ inches deep, which fits R-13 or R-15 batts. That meets the code alone in zones 1 and 2. Colder zones need a 2×6 wall or foam board on the outside as well.

How thick is R-30 insulation?

R-30 fiberglass batts are 9½ to 10¼ inches thick depending on the brand (8¼ inches for the high-density cathedral-ceiling version). Blown fiberglass needs about 12 inches for R-30, and blown cellulose about 9½ inches.

Is a higher R-value always better?

Higher R-value means more resistance to heat flow, but the gains shrink as you add more. Going from R-11 to R-30 in an attic saves far more than going from R-49 to R-60. Air sealing first usually matters more than the last few R-values.

Last reviewed 2026-10-21. Sources: 2021 IECC Table R402.1.3, 2018 IECC Table R402.1.2, ENERGY STAR, US DOE. See how we calculate.